Optical Biometer Ultrasonic Ophthalmology Abp Scanning Completed and Thickness Gauge

Optical Biometer Ultrasound Ophthalmic ABP Scan Complete with PachymeterCHE-SW3000A-SCANComplete and quick biometry :-   eye  axial length  (AXL)-   anterior chamber depth (AC)-   lens thickness (LENS)-   vitreous length (VITR)Measurement of all eye types:normal,  cataract,  dense cat

Featured Products

Optical Biometer Ultrasound Ophthalmic ABP Scan 
Complete with Pachymeter
CHE-SW3000


A-SCAN
Complete and quick biometry :
-   eye  axial length  (AXL)
-   anterior chamber depth (AC)
-   lens thickness (LENS)
-   vitreous length (VITR)
Measurement of all eye types:
normal,  cataract,  dense cataract, aphakic,silicone oil vitreous,
pseudoaphakic  (PMMA, ACRYLATE, SILICONE)
IOL six  formulas:
SRK II, SRK T, Holladay, Hoffer-Q, Binkhorst II, Haggis
Post refractive formulas:
Double-K SRKT,  Latkany / Flat-K SRKT/, Latkany /avg-K SRKT/, Masket
IOL power calculation comparison (for different lenses and calculation methods)
Contact and immersion methods  (the immersion tube  attached)
Probe with central light beam for correct eye positioning
Automatic TGC adjustment;GAIN adjustment up to 110dB
Memory of 20 scans with measurements for further analysis
Calculations of means and standard deviations
Automatic control of measurement scatters (with manual correction)
Customizable for 10 users,  10 profiles for each.
Adjusting  and testing via attached calibrator
Probe frequency - 12 MHz
Range of scan 40 mm
Clinical resolution   0.1 mm
Electronic resolution  -/+ 0.01 mm
     
B-SCAN
Probe frequency - 12/15 MHz
Scanning angle  - 55
Range of scan 20..60 mm
Gain/dymamics up to 110dB / 90dB
256 Levels Gray Scale
Axial clinical resolution  - 0.12 mm
Lateral clinical resolution -  0.3 mm
Display modes : B, B+A, B+B
A-mode for selected line CV (in Run and Freeze modes)
Dynamic Range Correction
Image cache memory  M1..M4  independent for right and left eyes
Zoom function (x2) in Run and Freeze modes
Digital Gain Correction in  Freeze mode
Cineloop function (about 6 second) independent for left/right eyes
Distances  measurements with ultrasound velocity correction
Area and angle measurements
Pointers, comments entered by the user
Composite video output for videoprinter
POWER  SUPPLY
Power supply from external  AC/DC power adapter:
-  input:  100-230V AC 50/60Hz /  max 0.7A
-  output:   +12V  DC / 2 A
Power consumption (12 DC supply) - ca 12 W

PACHYMETER
Quick  thickness measurements for all corneal  types
- automatic and manual measurements
- thickness measurement  at arbitrarily selected points
- calculation of mean from measurements
- standard deviation of the measured thickness
- ability for rejecting inaccurate measurements
Very high level of accuracy and repeatability of all measurements:
- sophisticated algorithms  for the accuracy improvement
- very high frequency for measuring purpose- 400 MH
- high averaging ratio - 512 automatic measurements cycles
Intra-ocular pressure (IOP) calculations with  measuring  and/or manual correction
Ten IOP correction formulas : Kohlhas/Shah, Argus et al. Whitarce et al, Doughty, Ehlers, Dresden, Stodmeister,  custom-own
BIAS percentage deviation of the measured thickness from 60% to 130%
TEST function for automatic checking of operation correctness  (without using external phantoms or patterns)
Nine corneal thickness maps with number of points:
1, 5, 9, 13, 21, 25, 1 MULTI, 5 MULTI, 9 MULTI
20 MHz probe operating frequency
400 MHz sampling rate
Default sound velocity - 1640 m/s ;  range from 1400 to 2000 m/s
Measurement  range from 220 μm to 1100 μm
Measuring accuracy <  ± 2 μm
Resolution 1 μm

GENERAL PROPERTIES
 Touch Screen
- easy, ergonomic and user-friendly operation via displayed menu
- virtual keyboard for entering patient data, etc.
Functional knob (gain control, review results, cine etc.)
Color LCD 7" display
Internal patient's databas
Ten (10) user profiles
Recording of images in internal and  USB-Pendrive memory.
Internal thermal small printer ( for A-scan and P-scan reports )
Composite-video output PAL (for videoprinter or  video monitor )
Support of multiple languages
Easy firmware upgrade via USB port
Optical Biometer Ultrasound Ophthalmic Abp Scan Complete with Pachymeter
Related Recommends
Classic Ent Examination Workstation Unit with Ent Doctor Chair

Company Information
Classic Ent Examination Workstation Unit with Ent Doctor Chair
FAQ
> if the machine broke after a period of use, can I return it back and get a refund?
iClear HealthCare has a secure procedure to do the product return and repair, please check our service
policy for more information.

 

> I have NO experience buying medical stuff in China. Is the quality good?
There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price.

 

> How long will it take to reach me after the payment?
By Express, it takes 5-7 working days to arrive;
By Air, 3-4 days to the international airport;
By Sea, around 25-55 days to the seaport.

 

>> Can you help set up a clinic or provide complete equipment for hospital projects?
We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers.
Contact Us
Optical Biometer Ultrasound Ophthalmic Abp Scan Complete with Pachymeter

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours